首页 > 按专业查询名词 > 查询PubMed相关文献
名词信息
Pubmed相关的文献
phantom-scattering fector相关文献:
An anthropomorphic body phantom for the determination of calibration factor in radionuclide treatment dosimetry.
Kovan B, Demir B, Işık EG, Has Şimşek D, Özkan ZG, Kuyumcu S, Türkmen C, Şanlı Y.
Radiat Prot Dosimetry. 2023 Jul 21;199(12):1274-1283. doi: 10.1093/rpd/ncad176.
PMID:37334429
[Effects of Phantom Factor on Shape Differences in Tomotherapy Water-equivalent Phantoms].
Ishita K, Tanabe Y, Sawahashi M, Yonaiguchi J, Takeda M, Sokawa T, Suenaga M, Abe K, Suzuki R, Sato Y.
Nihon Hoshasen Gijutsu Gakkai Zasshi. 2023 May 20;79(5):462-468. doi: 10.6009/jjrt.2023-1233. Epub 2023 Mar 9.
PMID:36889732
Quantitative Ultrasound: Scattering Theory.
Oelze M.
Adv Exp Med Biol. 2023;1403:19-28. doi: 10.1007/978-3-031-21987-0_2.
PMID:37495912
Attenuation correction for phantom tests: an alternative to maximum-likelihood attenuation correction factor-based correction for clinical studies in time-of-flight PET.
Mizuta T, Yamakawa Y, Minagawa S, Kobayashi T, Ohtani A, Takenouchi S, Hanaoka K, Watanabe S, Morimoto-Ishikawa D, Yamada T, Kaida H, Ishii K.
Ann Nucl Med. 2022 Nov;36(11):998-1006. doi: 10.1007/s12149-022-01788-8. Epub 2022 Sep 28.
PMID:36167889
Effect of anti-scatter grids on the image improvement factor in digital radiography for various phantom thicknesses and irradiation fields.
Tanaka N, Yoon Y.
Phys Eng Sci Med. 2023 Sep;46(3):1187-1192. doi: 10.1007/s13246-023-01285-w. Epub 2023 Jun 19.
PMID:37336831
Detection of Point Scatterers in Medical Ultrasound.
Thon SH, Hansen RE, Austeng A.
IEEE Trans Ultrason Ferroelectr Freq Control. 2022 Feb;69(2):617-628. doi: 10.1109/TUFFC.2021.3129619. Epub 2022 Jan 27.
PMID:34797764
3D scattering microphantom sample to assess quantitative accuracy in tomographic phase microscopy techniques.
Krauze W, Kuś A, Ziemczonok M, Haimowitz M, Chowdhury S, Kujawińska M.
Sci Rep. 2022 Nov 15;12(1):19586. doi: 10.1038/s41598-022-24193-7.
PMID:36380058
Mammography grid performance.
Rezentes PS, de Almeida A, Barnes GT.
Radiology. 1999 Jan;210(1):227-32. doi: 10.1148/radiology.210.1.r99dc35227.
PMID:9885613
[Improvement of Standardized Uptake Value Accuracy in the (99m)Tc Body SPECT and SPECT/CT: Optimization of the Phantom for Calculating Becquerel Calibration Factor and Correction Method].
Nakamura Y, Kangai Y, Abe T, Nakahara Y.
Nihon Hoshasen Gijutsu Gakkai Zasshi. 2021;77(9):921-931. doi: 10.6009/jjrt.2021_JSRT_77.9.921.
PMID:34544916
In phantom determination of collimator scatter factor.
Lam KL, Ten Haken RK.
Med Phys. 1996 Jul;23(7):1207-12. doi: 10.1118/1.597676.
PMID:8839414
© Copyright 2021 鸿泰茂源  版权所有All Rights Reserved京ICP备11040441号-3