首页 > 按专业查询名词 > 查询PubMed相关文献
名词信息
Pubmed相关的文献
percutaneous coronary bioabsorbable stent implantation相关文献:
Bioabsorbable polymer-coated sirolimus-eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub-study.
Rusinaru D, Vrolix M, Verheye S, Chowdhary S, Schoors D, Di Mario C, Desmet W, Donohoe DJ, Ormiston JA, Knape C, Bezerra H, Lansky A, Wijns W; DESSOLVE II Investigators.
Catheter Cardiovasc Interv. 2015 Dec 1;86(7):1141-50. doi: 10.1002/ccd.25610. Epub 2015 Sep 22.
PMID:25044635
A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial.
de Winter RJ, Katagiri Y, Asano T, Milewski KP, Lurz P, Buszman P, Jessurun GAJ, Koch KT, Troquay RPT, Hamer BJB, Ophuis TO, Wöhrle J, Wyderka R, Cayla G, Hofma SH, Levesque S, Żurakowski A, Fischer D, Kośmider M, Goube P, Arkenbout EK, Noutsias M, Ferrari MW, Onuma Y, Wijns W, Serruys PW.
Lancet. 2018 Feb 3;391(10119):431-440. doi: 10.1016/S0140-6736(17)33103-3. Epub 2017 Dec 5.
PMID:29203070
The relation of polymer structure of stent used in patients with acute coronary syndrome revascularized by stent implantation with long-term cardiovascular events.
Yaylak B, Polat F, Onuk T, Akyüz Ş, Çalık AN, Çetin M, Eren S, Mollaalioğlu F, Kolak Z, Durak F, Dayı ŞÜ.
Catheter Cardiovasc Interv. 2023 Dec;102(7):1186-1197. doi: 10.1002/ccd.30881. Epub 2023 Oct 19.
PMID:37855201
Twilight-specific light cues.
Tarantini G, Fraccaro C.
Catheter Cardiovasc Interv. 2021 Jan 1;97(1):72-73. doi: 10.1002/ccd.29443.
PMID:33460272
Elastic stent recoil in coronary total occlusions: Comparison of durable-polymer zotarolimus eluting stent and ultrathin strut bioabsorbable-polymer sirolimus eluting stent.
Improta R, Scarparo P, Wilschut J, Wolff Q, Daemen J, Den Dekker WK, Zijlstra F, Van Mieghem NM, Diletti R.
Catheter Cardiovasc Interv. 2022 Jan 1;99(1):88-97. doi: 10.1002/ccd.29739. Epub 2021 May 7.
PMID:33961730
Safety and efficacy of Everolimus-Eluting bioabsorbable Polymer-Coated stent in patients with long coronary lesions: The EVOLVE 48 study.
Karmpaliotis D, Stoler R, Walsh S, El-Jack S, Potluri S, Moses J, Oldroyd K, Banning A, Webster M, Zaman A, Wu W, Ahmed M, Underwood P, Allocco D.
Catheter Cardiovasc Interv. 2022 Feb;99(2):373-380. doi: 10.1002/ccd.29798. Epub 2021 May 29.
PMID:34051049
Efficacy and safety of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent: the EVOLVE II Randomized Trial.
Kereiakes DJ, Meredith IT, Windecker S, Lee Jobe R, Mehta SR, Sarembock IJ, Feldman RL, Stein B, Dubois C, Grady T, Saito S, Kimura T, Christen T, Allocco DJ, Dawkins KD.
Circ Cardiovasc Interv. 2015 Apr;8(4):e002372. doi: 10.1161/CIRCINTERVENTIONS.114.002372.
PMID:25855680
Therapies targeting inflammation after stent implantation.
Okura H, Takagi T, Yoshida K.
Curr Vasc Pharmacol. 2013 Jul;11(4):399-406. doi: 10.2174/1570161111311040004.
PMID:23905635
Coronary artery perforation after bioresorbable scaffold implantation treated with a new generation covered stent-OCT insights.
Chen D, Gadeley R, Wang A, Jepson N.
BMC Cardiovasc Disord. 2022 Feb 23;22(1):66. doi: 10.1186/s12872-022-02501-3.
PMID:35196989
Two-year clinical registry follow-up of endothelial progenitor cell capture stent versus sirolimus-eluting bioabsorbable polymer-coated stent versus bare metal stents in patients undergoing primary percutaneous coronary intervention for ST elevation myocardial infarction.
Chong E, Poh KK, Liang S, Lee RC, Low A, Teo SG, Tan HC.
J Interv Cardiol. 2010 Apr;23(2):101-8. doi: 10.1111/j.1540-8183.2010.00534.x. Epub 2010 Mar 2.
PMID:20236214
© Copyright 2021 鸿泰茂源  版权所有All Rights Reserved京ICP备11040441号-3